BVS ID-M1280xF1-xx-xxx
Event
Event Type
Code
0x8D10
Warning
(36112)
0x8D20
Warning
(36128)
Variant Dependence
The functionality is available in all variants.
Inclination and Installation Aid
Description
This feature offers two functions:
Inclination detection
Installation and alignment aid
The inclination aid detects a deviation in the inclination compared to a reference position. The reference position
can be freely selected and taught in.
The internal position sensor follows the vertical earth axis. Angular deviations to this axis can be recognized,
parallel  shifts to the axis or rotation around this axis cannot.
Measurement data for inclination detection:
Measurement range: 0...180°
Resolution: 1°
Accuracy: +/−1°
Measurement period: 1000 ms (data refresh rate = 1 second)
With the inclination detection it can be recognized whether the BVS ID has changed its original installation
position and therefore a possible misalignment and resulting malfunctions can be detected at an early stage.
The configuration can be performed via ISDU parameters.
Using the feature
1.
Switch on, establish IO-Link communication.
2.
Send system command 0xC0.
→ The inclination measurement data is available via ISDU (e.g., 0x2154) or via the process data.
Recognizable adjustments
142
  english
Event – Description – Remedy
Device Temperature Upper Warning – The set
upper temperature warning threshold has been
exceeded.
Device Temperature Lower Warning – The set
lower temperature warning threshold is below the
minimum value..
Device Status
0 – Device is operating
properly.
0 – Device is operating
properly.