Parameters
Description
Active
Activates or deactivates the reading of a reference value.
String Length
Number of bytes representing the characters of the reference value.
New Reference
If New Reference Per Cycle is activated, the input buffer representing the
Per Test Cycle
read in reference value is deleted after completion of an inspection program
run. The reference value can thus no longer be used in the following
inspection program run.
If New Reference Per Cycle is deactivated, the reference value is reused
until it is overwritten by a newly received data container.
NOTE
Changing between configuration and monitor mode causes the reference value to be discarded if New
Reference Per Cycle is activated. If it is deactivated the reference value is retained in this case.
Changing the inspection program causes the reference value to always be discarded. For every new
inspection program a new data container has to be sent.
22
  english
Data
type
Bool
Uint16
Bool