Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BVS ID-M1280-F1-Serie Konfigurationsanleitung Seite 256

Vorschau ausblenden Andere Handbücher für BVS ID-M1280-F1-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

 
BVS ID-M1280xF1-xx-xxx
Structure protocol byte 0 (BVS ID → PLC) State Bytes
Name
OK
OK Inspection ID
OK Results
OK Date Time
NOK Error
NOK Communication Abort
NOK Invalid Command
NOK Results
NOK Busy
NOK Inspection Error
Positive results (OK ....) are signalled with the Job End bit during the handshake.
Negative results (NOK ...) are signalled with the Job Error bit during the handshake.
Negative results (NOK...) have no payload and always a length of 0.
82
  english
Status code
Meaning
00
Command was successfully executed.
hex
02
Response to the command Get Inspection ID;
hex
transfer of
03
Response to the command Get Results; transfer
hex
of results.
06
Response to the command Get Date Time;
hex
transfer of timestamp.
10
An error occurred during the last transfer of a
hex
command.
11
Communication was canceled by the PLC by
hex
resetting the Job bit.
13
An invalid command code was transferred.
hex
15
Response to the command Get Results; no
hex
results present.
16
Command could not be executed since the
hex
camera is still processing another command or
is not yet ready after a restart.
1A
An error occured while loading the inspection
hex
program.
the inspection
ID.