4.4.5 Programming the F-Blocks (save input data)

The programming and modification of the Main_Safety_RTG1 (FB1) block, for
saving the measuring system input data, are performed below.
PLC tags -> Default tag table
First of all the tags for "Position" and "Velocity" are defined in a tag table. To do
this, go to Project tree and in the directory tree select the entry CD_582_-
EPN_PROFIsafe -> PLC_1 [CPU 1511F-1 PN] -> PLC tags ->
Default tag table [66] by double-clicking with the left mouse button. The
tag editor opens in the work area.
The following tags are defined in the tag editor for the measuring system input
data:
Printed in the Federal Republic of Germany
12/17/2020
Position:
Name: IN_Pos_Safety
Data type: DInt
Address: %ID2
Velocity:
Name: IN_Velo_Safety
Data type: DInt
Address: %ID6
TR - ECE - TI - DGB - 0340 - 01