BTL7-S5 _ _ ( _ )-M _ _ _ _ -BE/BF/CE/ZE/ZF-S32/S115/KA _ _ /FA _ _
Magnetostrictive Linear Position Sensor — Rod Style
4
Installation and connection (continued)
Magnet
(e.g. BTL-P-1028-15R)
Supporting rod made of non-magnetizable material
Fig. 4-9:
Example 2, BTL installed with supporting rod
4.4
Electrical connection
Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-2 to Tab. 4-4.
Note the information on shielding and cable
routing on page 12.
4.4.1
Connector type S32
BTL7 standard
Pin
BTL7-S5_ _...-S32
1
+Clk
2
+Data
3
–Clk
4
Not used
1)
5
–Data
6
GND
7
10...30 V
8
Not used
1)
Unassigned leads can be connected to the GND on the controller side
1)
but not to the shield.
Communication line
2)
Tab. 4-2:
Connection assignment BTL7...-S32
Fig. 4-10: Pin assignment of S32 (view of connector pins of BTL),
8-pin M16 circular plug
www.balluff.com
BTL7 USB
configurable
BTL7-S510...-S32
+Clk
+Data
–Clk
La
2)
–Data
GND
10...30 V
Lb
2)
4.4.2
Connector type S115
BTL7 standard
Pin
BTL7-S5_ _...-S115
1
+Clk
2
+Data
3
–Clk
4
Not used
1)
5
–Data
6
GND
7
10...30 V
8
Not used
1)
Unassigned leads can be connected to the GND on the controller side
1)
but not to the shield.
2)
Communication line
Tab. 4-3:
Connection assignment BTL7...-S115
Fig. 4-11: Pin assignment of S115 (view of connector pins of BTL),
8-pin M12 circular plug
BTL7 USB
configurable
BTL7-S510...-S115
+Clk
+Data
–Clk
La
2)
–Data
GND
10...30 V
Lb
2)
english