BTL7-V50T-M _ _ _ _ -P-SA479-C003/ _ _ _ _
Magnetostrictive Linear Position Sensor – Set
Install position magnet (continued)
In order to ensure safe function, a positioning
diagram must be observed (see tables in
BTL7-V50T user's guide).
Observe the following when installing the position magnet:
–
To ensure the accuracy of the position measuring
system, the position magnet is fastened to the machine
part with non-magnetizable screws (stainless steel,
brass, aluminum). The distance A between the position
magnet and parts made of magnetizable material must
be at least 20 mm.
–
The position magnets must be mounted on a raceway
parallel to the magnetostrictive linear position sensor
(BTL).
–
The following values must be observed:
Designation
Distance between position magnet
and parts consisting of magnetizable
material (A)
Distance between position magnet
and BTL (B)
Value range
Ideal value
Center offset (C)
Value range
Ideal value
www.balluff.com
Install position magnet (continued)
≥ 20 (A)
Value
≥ 20 mm
–
The installation height of the position magnets may vary
12...56 mm
by maximum ±5 mm for safe operation of the system.
34 mm
≤ 40 mm
0 mm
Electrical connection
40 (C)
40 (C)
Information on the electrical connection and
cable routing of the position measuring system
can be found in the BTL7-V50T... user's guide.
english
≥ 20 (A)
3