BTL7-S5 _ _ ( _ )-M _ _ _ _ -BE/BF/CE/ZE/ZF-S32/S115/KA _ _ /FA _ _
Magnetostrictive Linear Position Sensor — Rod Style
8
Technical data (continued)
8.7
Connection to the evaluation unit
The maximum sampling frequency f
current value is available with each sampling, can be found
in the following graphic:
f
in Hz
A,max
Fig. 8-1:
Maximum sampling rate depending on the nominal length
(for position output) The maximum sampling rate for velocity
output is limited to 3.3 kHz.
The maximum SSI clock frequency f
the cable length
:
1)
f
in kHz
Clk,max
Fig. 8-2:
Maximum SSI clock frequency depending on the cable length
20
english
, at which a new
A,max
is dependent on
CLK, max
The minimum sampling frequency f
Nominal length in mm
Cable length in m
1)
For longer length: required cable cross-section ≥ 0.6 mm
is 62,5 Hz.
A,min
(1) 1 magnet
(2) 2 magnets
(only BTL7-S510...)
2
or ≤ AWG19