Testing the Twin
Complete System
1
2
3
4
(1)
Disconnect the hosepacks from the system components
Remove the gas nozzle from the torch neck of the Twin complete system
Screw the Twin complete system onto the mounting block (1)
Check the position of the contact tips by pressing on the spring (2)
-
The Twin complete system is okay if the test probes (3) fit perfectly into the wire
outlet openings of the contact tips
-
If this is not the case, the Twin complete system with mounting block must be re-
adjusted
(3)
(2)
85