In this section, up to 32 configurations (samples) can be defined for colour detection and also be linked with one
another. The formation of configuration groups is also possible. Following selection of the appropriate radio button
(1-32), the data for the configuration selected appear in the section „C Parameter active configuration" where they
can be set.
In the area „Select Configuration" all 32 single results are displayed. In each configuration, e.g. with the Vision
Sensor, one LED for the primary result = part detected = Q1, and one LED for the secondary result = Position OK/
NOK = Q2, and the bargraph = degree of similarity with the taught pattern, is displayed with its threshold. This feature
increases the transparency and eases the test and optimitation of the parameter settings a lot.
The grouping of configurations makes it possible to check several characteristics on different
parts (e.g. change of parts by charge during production process with, for example, 4-5 characte-
ristics per part).
With different configurations any type of evaluation method can be used
(e.g. Config 1 = Pattern, Config2 = Contrast, etc.).
Section
Setting rules for:
- Illumination
- Function IN2
- Trigger mode
- Teach shutter /manuall = "manual"
- Baud rate RS422
- Shutter
- Trigger delay
- Result delay
- Result period
- Outputs active
- Threshold value
74
Field name
Logic
= identical
= identical
= "triggered"
= identical
= identical
= identical
= identical
= identical
= identical
= any
Description
The defined configuration data / samples can be logically
linked with one another to adapt the evaluation function to the
required application. For logical linking, the configurations con-
cerned are marked by a tick and allocated an operator from the
list „Logic". In all cases, only one operator can be selected.
The configuration for which the parameters are to be set is
selected with radio buttons 1-32.
Since the evaluation is based on one image only,
all the configurations used with „Logic" must be
taught using the setting rules opposite and then
saved. The settings refer to config. 1 or the last
configuration activated.
To adjust several parameters of several configu-
rations identically in an easy way, use function
„copy"
In operation with a process control (see chapter
8.1) the start configuration/group is selected
using IN2 or the serial interface (see chapter 6
Formats for serial output).
FA 45 Vision Sensor - Colour Sensor GB - 068-13760 - 05.06.2008-01