Proceeding/Troubleshooting - Direct Connection
Creating a functioning ethernet connection between FA 45 Vision Sensor and PC
Important:
To configure the PC via Direct Connection it is neccessary to change it´s IP- configuration.
Please contact your system administrator to inform about changes !
Sensor correctly connected?
- Power supply 24V DC
- Networkcable (crossed) Nr. 902-51736
yes
Electrical connection OK?
- green Pwr LED at FA 45 active?
- Status LED at networkadapter active?
- and/or LAN Status shows "Connection
established". (Control panel
connections
LAN-Connection
yes
IP address of PC fits to IP of Sensor?
Sensor IP: 192.168.100.100/24 (default)
- PC: e.g. 192.168.100.101/24
( /24 means, 24Bit Subnetmask =
255.255.255.0)
yes
SensoFinder finds Sensor?
- start SensoFinder
- press button "Find"
- mark Sensor
- Button "Connect" is aktive?
yes
SensoFinder starts applicaiton- software?
- Double click on sensor in the list
- PC / application- software starts
yes
Now the parameter setting of the sensor /
application can be done
FA 45 Vision Sensor - Colour Sensor GB - 068-13760 - 05.06.2008-01
yes
no
Network-
Status)
yes
no
Configuration: Start
LAN-Connection
yes
Please contact your system administrator as this can cause
Start
no
If four positive answers are displayed, go on with "Yes"- path
Start
After parameter setting is finished, reactivate firewall again!
yes
no
Sensorversion is displayed in the SensoFinder (e.g. 40). Table of
compatibility and corresponding software at www.sensopart.com
Connect Sensor correctly!
- Power supply 24V DC
- Networkcable (crossed) Nr. 902-51736
no
Control / correct settings
- IP of PC (fix, to the sensor corresponing IP):
e.g. 192.168.100.101; - Subnetmask: 255.255.255.0
Control panel
Properties
"Repair" Networkconnection
problems!
Control panel
Networkconnections
on used "LAN connection"
(delets ARP Cache, amongst others).
IP-Connection test
- in Command
Line:
ping 192.168.100.100
(IP address of the sensor) [ENTER] .
(Command input:
All Programs
Accessories
no
Deacticate / adapt firewall
Please contact your sytem administrator
IP-Connection test (see above)
Caution!
Sensor- and Softwareversion test
Networkconnections
Internetprotocol (TCP/IP)
Right mouse click
Repair
Command Line)
yes
Fig. 8
155-00509
no