Mounting and
operating instructions
3.2.1.2 Focusing screw
Focusing screw to adjust focus.
3.2.1.3 24 V DC Connection
M12 Connection socket for 24 V DC voltage supply and digital I/O.
The exact plug connection see table2, chapter 8.7.
Should the parameter of the active configuration „Function IN2" be set to „Enable"
(manufacturer's setting), the input IN2 must be connected to +U
operate the FA 45 Vision Sensor with an external trigger (input IN1). If no +U
the FA 45 Vision Sensor will not execute evaluation. In this case it is in standby mode (= Disable).
(See chapter 8.1).
3.2.1.4 LAN Connection
M12 Connection socket for Ethernetconnection.
The exact plug connection see table 3, chapter 8.7.
Use only the correct network cables (see accessories table chapter 8.12).
Direct connection of the FA 45 Vision Sensor to a PC: (recommended):
FA 45
Fig. 4
155-00535
alternatively
Fig. 5
155-00458
Connection of the FA 45 Vision Sensor to a PC via a network:
FA 45
Fig. 6
155-00459
3.2.1.5 Data (RS422) Connection
M12 Connection socket for DATA serial interface, RS422.
The exact plug connection see table4, chapter 8.7.
FA 45 Vision Sensor - Colour Sensor GB - 068-13760 - 05.06.2008-01
Ethernet cable (crossover)
CI L8FSK/RJ45S-xm-GG-PVC-G
M12
Ethernet cable (straight)
FA 45
CI L8FSK/RJ45S-xm-GG-PVC
M12
Ethernet cable (straight)
CI L8FSK/RJ45S-xm-GG-PVC
M12
RJ45
Ethernet-
connector
AA-RJ45
RJ45
Network
e.g. switch, hub etc.
RJ45
RJ45
Standard
network cable
(= High = Enable) in order to
B
is connected to IN2,
B
PC
Ethernet
cross cable
PC
CI RJ45-1mK
RJ45
RJ45
PC
RJ45
61