Parameter
Liste der Parameter
Bitfeld:
Bit
Signalname
00
DI 0 (X122.1 / X121.1)
01
DI 1 (X122.2 / X121.2)
02
DI 2 (X122.3 / X121.3)
03
DI 3 (X122.4 / X121.4)
04
DI 4 (X132.1 / -)
05
DI 5 (X132.2 / -)
06
DI 6 (X132.3 / -)
07
DI 7 (X132.4 / -)
08
DI/DO 8 (X122.9 / X121.7)
09
DI/DO 9 (X122.10 / X121.8)
10
DI/DO 10 (X122.12 / X121.10)
11
DI/DO 11 (X122.13 / X121.11)
12
DI/DO 12 (X132.9 / X131.1)
13
DI/DO 13 (X132.10 / X131.2)
14
DI/DO 14 (X132.12 / X131.4)
15
DI/DO 15 (X132.13 / X131.5)
16
DI 16 (X122.5 / X120.3)
17
DI 17 (X122.6 / X120.4)
20
DI 20 (X132.5 / X120.9)
21
DI 21 (X132.6 / X120.10)
Abhängigkeit:
Siehe auch: r0723
Achtung:
Zur Klemmenbezeichnung:
Die erste Bezeichnung gilt für CU320, die zweite für CU310.
Hinweis:
DI: Digital Input (Digitaleingang)
DI/DO: Bidirectional Digital Input/Output (Digitaleingang/-ausgang bidirektional)
r0723.0...21
CO/BO: CU Digitaleingänge Status invertiert / CU DI Status inv
CU_G130_DP,
Änderbar: -
CU_G130_PN,
Datentyp: Unsigned32
CU_G150_DP,
CU_G150_PN
P-Gruppe: Befehle
Nicht bei Motortyp: -
Min
-
Beschreibung:
Anzeige des invertierten Status der Digitaleingänge.
Bitfeld:
Bit
Signalname
00
DI 0 (X122.1 / X121.1)
01
DI 1 (X122.2 / X121.2)
02
DI 2 (X122.3 / X121.3)
03
DI 3 (X122.4 / X121.4)
04
DI 4 (X132.1 / -)
05
DI 5 (X132.2 / -)
06
DI 6 (X132.3 / -)
07
DI 7 (X132.4 / -)
08
DI/DO 8 (X122.9 / X121.7)
09
DI/DO 9 (X122.10 / X121.8)
10
DI/DO 10 (X122.12 / X121.10)
11
DI/DO 11 (X122.13 / X121.11)
12
DI/DO 12 (X132.9 / X131.1)
13
DI/DO 13 (X132.10 / X131.2)
14
DI/DO 14 (X132.12 / X131.4)
15
DI/DO 15 (X132.13 / X131.5)
16
DI 16 (X122.5 / X120.3)
17
DI 17 (X122.6 / X120.4)
20
DI 20 (X132.5 / X120.9)
21
DI 21 (X132.6 / X120.10)
Abhängigkeit:
Siehe auch: r0722
1-242
1-Signal
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
Berechnet: -
Dyn. Index: -
Einheitengruppe: -
Normierung: -
Max
-
1-Signal
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
High
© Siemens AG 2003 - 2013 All Rights Reserved
SINAMICS G130/G150 Listenhandbuch (LH2), 01/2013, A5E03263478A
0-Signal
FP
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Zugriffsstufe: 1
Funktionsplan: 1510, 2020,
2030, 2031, 2100, 2120, 2130,
2131, 2132, 2133
Einheitenwahl: -
Expertenliste: 1
Werkseinstellung
-
0-Signal
FP
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-
Low
-