9.1.2.2 Object 6002h - Total measuring range in measuring units
The parameter "Total measuring range in measuring units" sets the number of steps
about the total measuring range before the measuring system restarts at zero.
Unsigned32
Byte 0
7
2
lower limit
upper limit
default
The actual upper limit for the Total measuring range in measuring units to be entered
is dependent on the measuring system version and can be calculated with the formula
below. As the value "0" is already counted as a step, the end value = Total measuring
range in measuring units – 1.
Total measuring range in measuring units = Steps per revolution * Number of revolutions
To calculate, the parameters Steps per revolution and the Number of revolutions
can be read on the measuring system nameplate.
The parameter "Number of revolutions", which results from the inputs "Total
measuring range in measuring units" and" Steps per revolution", has the following
restrictions:
Maximal Number of revolutions: 256.000
-
2-digit comma number, more than two digits cause an automatic correction. The
-
actual value can be obtained by reading the objects 6001h and 6002h.
Infinite digits with comma numbers period 3 or 6
-
Printed in the Federal Republic of Germany
02/02/2016
Danger of personal injury and damage to property exists if the measuring
system is restarted after positioning in the de-energized state by shifting
of the zero point!
If the number of revolutions is not an exponent of 2 or is >4096, it can occur, if
more than 512 revolutions are made in the de-energized state, that the zero
point of the multi-turn measuring system is lost!
Ensure that the Number of revolutions for a multi-turn measuring system is
an exponent of 2 of the group 2
or
 Ensure that every positioning in the de-energized state for a multi-turn
measuring system is within 512 revolutions.
Total measuring range in measuring units
Byte 1
0
15
8
to 2
2
to 2
16 steps
33554432 steps (25 bit)
16777216
TR - ECE - BA - DGB - 0038 - 05
0
1
2
12
, 2
, 2
...2
(1, 2, 4...4096).
Byte 2
Byte 3
23
16
31
2
to 2
2
to 2
 TR-Electronic GmbH 2006, All Rights Reserved
24
Page 99 of 112

Werbung

loading