Communication-Specific Standard Objects (CiA DS-301)
Sub-Index
Description
Category
Data type
Access
PDO mapping
Default value
Value range
The value is created by a configuration tool in a manufacturer specific way.
In an EPL network the ID number should be identical only on those nodes, which have
an identical hardware and configuration besides some node specific parameters like
EPL Node-ID or the Serial-Number etc. Otherwise the ID number should be unique for
each node in an Ethernet POWERLINK network segment.
Sub-Index
Description
Category
Data type
Access
PDO mapping
Default value
Value range
VerifyConfInvalid_BOOL enables temporary local modifications of configuration
parameters for test purpose while maintaining the bootability of the network.
VerifyConfInvalid_BOOL = FALSE indicates that the configuration was not
modified since the last storage of ConfId_U32 (sub-index 03h).
A change of a parameter which is stored in permanent memory sets
VerifyConfInvalid_BOOL to TRUE.
VerifyConfInvalid_BOOL is set to FALSE upon writing a value > 0 to ConfId_U32.
A configuration tool or an application may use this information to display a warning if
the configuration of a node was modified.
 TR-Electronic GmbH 2008, All Rights Reserved
Page 152 of 203
003
ConfId_U32,
contains the ID number for the configuration
Optional
UNSIGNED32
rw
no
0
0...0xFF FF FF FF
004
VerifyConfInvalid_BOOL
Optional
BOOLEAN
ro
no
0
0...0x1; 0 = FALSE, 1 = TRUE