Instructions for mounting / schematic

4.3 Assembly diagram of the rod housing design

A:
The linear transducer is fixed directly with the thread or a nut/mother with the
mounting plate, with one attraction moment of < 50 Nm.
The mounting material for the way sensor and position sensor B should absolutely
consist of not magnetizable material.
C:
If magnetizable mounting material is used, a spacer from not magnetizable material
with 10 mm thickness and min. 3 mm must be planned more largely in the distance to
the extent of the position sensor. The spacer is to be installed between the position
sensor and its attachment. The screws must be from not magnetizable material.
D:
The hydraulic sealing at the flange contact surface is recommended by means of
O-ring in a cylinder soil groove. It can take place the sealing also with an O-ring in the
thread runout groove.
E:
Horizontal inserted rods > 1.5 m long should be supported and a position sensor
open to the extent be used.
F:
Optionally the linear transducer can be supplied at the tubing point with a blind hole
thread M4x5. This can be used for the rod end bearing.
The maximum values for Vibration and Shock specified in the product data
sheets are only achieved if the measuring system is firmly mounted or damped
on both sides. Not "freely vibrating".
 TR-Electronic GmbH 2007, All Rights Reserved