If more than one voltage is specified on the data plate, the tumble
dryer can be converted for connection to the relevant input voltage.
This conversion must be performed by the Miele Customer Service
Department or by an authorised dealer. During the conversion, the
wiring instructions given on the wiring diagram must be followed.
Tip: We recommend connecting the tumble dryer to the power supply
via a plug and socket so that it is easier to conduct electrical safety
checks (e.g. during maintenance or repair work).
It is recommended the tumble dryer is connected with a suitable plug
and socket in accordance with IEC 60309-1, however if the installa-
tion requires a hard-wired connection, an all-pole means of isolation
must be provided on site. Switches with a minimum contact gap
greater than 3 mm are suitable disconnectors. These include circuit
breakers (MCB), fuses and contactors (VDE 0660) (IEC/EN 60947)
If the mains supply cannot be permanently disconnected, the isolation
device (including plug and socket) must be safeguarded against being
switched on either unintentionally or without authorisation.
The tumble dryer must not be connected to devices such as timers
which would switch it off automatically.
Limitations to dryer operation due to reconnecting/removing jump-
ers.
Modifying/removing jumpers at the heater elements in order to set
lower heater ratings may result in limitations to dryer operation. De-
pending on the type of laundry, length of vent ducting, and outside
temperature, the desired drying results may no longer be achieved.
In the event of a reduction, the specified consumption data will no
longer be achieved.
If it is necessary to install a residual current device (RCD) in accord-
ance with local regulations, a residual current device type B (sensitive
to universal current) must be used.
Air intake/exhaust air
The tumble dryer may only be operated when the ducting has been
connected properly and the room is sufficiently ventilated.
 Risk of electric shock and injury due to using the tumble dryer
without the complete casing.
If the casing is dismantled, it is possible to come into contact with
live or rotating machine parts.
Once the tumble dryer has been installed, replace all the casing
parts that were removed.
en - Installation