Final residual moisture
6 % (dry) – 40 % (damp)
-
Extra drying time
:
0–60 minutes
-
(Process air):
Temperature
cold – 75 °C
-
Cooling down temperature
40–55 °C
–
Drum rotation, main direction
20–600 seconds
–
Pause:
2–15 seconds
–
Drum reversal
20–600 seconds
-
Anti-crease
–
Drum rotation, main direction
0–500 seconds
–
:
Pause
100–3000 seconds
–
Drum reversal
0–500 seconds
:
Timed drying
-
Running time
:
5–180 minutes
-
(Process air):
Temperature
cold – 75 °C
-
Cooling down temperature
40–55 °C
–
Drum rotation, main direction
20–600 seconds
–
Pause:
2–15 seconds
–
Drum reversal
20–600 seconds
-
Anti-crease
–
Drum rotation, main direction
0–500 seconds
–
Drum reversal
0–500 seconds
–
:
Pause
100–300 seconds
Sort programmes
Programmes can be moved within the programme list and in the Favourites list.
:
(Process air):
:
:
:
:
(Process air):
:
:
:
:
en - Supervisor level
83