4 Product description
4.4 Technical data
Tab. 2
Ambient temperature
Relative humidity
1
Tab. 3
Ambient temperature
Relative humidity
Max. tilt angle
1
Tab. 4
Mains voltage
Number of phases
Rated frequency
Max. current consumption
Max. power consumption
Fuse on mains side
Welding current range
Working voltage
Idle power consumption
Idle voltage
Duty cycle 100% (+40°C)
Duty cycle 60% (+40°C)
Duty cycle 50% (+40°C)
Protection type
Type of cooling
Total weight with cooling
unit
Weight without cooling
unit
Dimensions (L × W × H)
Without cooling unit and
driving carriage
Dimensions (L × W × H) of
entire device with cooling
unit
A duty cycle of 60% means that the device rests for 4 minutes after 6 minutes of welding with the maximum
current.
EN - 16
Ambient conditions for transport and storage
In accordance with EN IEC 60974-1
Ambient conditions for operation
In accordance with EN IEC 60974-1
Technical data
410 A/34.5 V pulse
395 mm × 710 mm ×
395 mm × 710 mm ×
iROB
1
20% to 80% (non-condensing)
1
20% to 80% (non-condensing)
®
iROB
501
iROB
400 V ±15%
3 phases
50/60 Hz
36 A
29 A
25 kVA,
20.1 kVA, 18.1 kW
22.9 kW
32 A; slow-blow
30 A to 500 A
30 A to 400 A
15.5 V to 39.0 V
15.5 V to 34.0 V
87.6 W
78.7 W
80 V maximum
80 V maximum
370 A/32.5 V pulse
500 A/39.0 V DC
380 A/33.0 V DC
—
400 A/34.0 V DC
IP 23
Liquid-cooled
114 kg
93 kg
(cooling unit 31 kg)
(cooling unit 31 kg)
83 kg
62 kg
395 mm × 710 mm ×
762 mm
592 mm
395 mm × 710 mm ×
1158 mm
775 mm
®
®
®
501, iROB
401, iROB
301
−20°C to +55°C
−10°C to +40°C
10°
®
®
401
iROB
301
21.8 A
15.2 kVA, 13.5 kW
30 A to 320 A
15.5 V to 30.0 V
78.7 W
80 V maximum
280 A/28.2 V pulse
320 A/30.0 V pulse
—
Air-cooled
—
62 kg
395 mm × 710 mm ×
592 mm
—