Herunterladen Inhalt Inhalt Diese Seite drucken

Emergency Information; Product Description; Technical Data - Abicor Binzel xFUME PRO Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für xFUME PRO:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
®
xFUME
PRO/xFUME
COMPACT
► Observe the warning signals and indicators on the fume
extraction system. Warning signals and indicators can imply
a saturated filter or a problem with/damage to the fume
extraction torch.
► Replace the extraction-specific wear parts at regular
intervals. The replacement interval required depends on the
application conditions.
2.6 Safety instructions for personal protective equipment
► Do not wear loose fitting clothing or jewelry.
► Use a hair net for long hair.
2.7 Safety instructions for use
► Do not exceed the maximum load data as defined by the
documentation supplied. Excessive loads lead to irreparable
damage.
2.8 Classification of the warnings
The warnings used in the operating instructions are divided into
four different levels and shown prior to potentially dangerous
work steps. Arranged in descending order of importance, they
have the following meanings:
DANGER
Describes an imminent threatening danger. If not avoided, it may cause severe injuries or death.
WARNING
Describes a potentially dangerous situation. If not avoided, this may result in death or serious injuries.
CAUTION
Describes a potentially harmful situation. If not avoided, this may result in slight or minor injuries.
NOTICE
Describes the risk of impairing work results or material damage and indicates irreparable damage to the device or equipment.

2.9 Emergency information

► In the event of an emergency, immediately disconnect the
following supplies: electrical power supply, compressed air
supply, coolant supply and shielding gas supply.

3 Product description

3.1 Technical data

Tab. 1
General torch data (EN 60974-7)
Temperature
(transport and storage)
Temperature (operation)
Relative humidity
Type of use
Type of voltage
Polarity of the electrodes for DC Usually positive
► Open the air regulator for only a moment and close it
► Observe the instructions on the adapter label for connecting
► Wear safety goggles, protective gloves and, if required,
► Do not make any constructive changes to this device.
► During welding work outdoors, use suitable protection
► Consult the documentation for welding components.
−25 °C to +55 °C
Shielding gas
(DIN EN ISO 14175)
−10 °C to +40 °C
Wire types
Up to 90% at 20 °C
Voltage rating
Hand-held
Protection type of the device
connections (EN 60529)
DC
Control features in the handle For 42 V and 0.1 to 1 A
quickly after opening it. The air regulator must be closed to
ensure efficient capture of fumes.
components.
a breathing mask when the device is in use and when
welding.
against the weather conditions.
CO
Commercially available
round wires
Peak value of 113 V
IP3X
3 Product description
and mixed gases M21
2
EN - 13

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Xfume compact

Inhaltsverzeichnis