Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 125

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
®
iROB
501, iROB
401, iROB
F64: Fine adjustment of the pulse peak time in the low pulse phase
This function allows for the fine adjustment of the standard pulse peak time in the iArc mX Move DC welding
procedure on the "low" side.
Adjustable range
Default value
Storage option
Description
F65: Fine adjustment of the base current in the low pulse phase
This function allows for the fine adjustment of the base current in the iArc mX Move DC welding procedure
on the "low" side.
Adjustable range
Default value
Storage option
Description
F66: Adjusting the feed amplitude ratio
This function defines the feed amplitude ratio (change in amplitude of the wire feed speed) in the
iArc mX Move DC welding procedure. If the move-frequency is below 5 Hz, the wire feed speed is adjusted.
Fine adjustment of the feed speed allows the welding result to be optimized for the specific application.
The adjustment can be set in the range of 0 to 100%. Here, 50% is the standard value. The relationship
between the set value and the welding result is shown in the following table.
Tab. 16
Parameters
Changes to the wire feed
Changes to the arc
Change in flaking
Reduction of cavity
Movement speed used
Permissible gap
*1 For steel and stainless steel, a setting of 50% (standard) or even 100% may show no effect as the
Adjustable range
Default value
Storage option
Description
F67: Setting the selection of current values (start welding parameter, end crater parameter)
When the end crater filler function is switched on, the current value for the start parameter and the end crater
parameter can be set in % based on the present value of the welding current in functions F68 and F69.
Adjustable range
Default value
Storage option
Description
®
301
−1.5 to +1.5 ms
0 ms
Yes
Defines the pulse time adjustment value in the low pulse phase.
−60 to +60 A
0 A
Yes
Defines the base current adjustment value in the low pulse phase.
Feed amplitude ratio
material will level out before it hardens.
0 to 100%
50%
Yes
Defines the feed amplitude ratio of the wire feed for move pulse welding.
ON/OFF
OFF
No
ON: Setting in % possible.
OFF: Function deactivated.
0% (minimum value)
None (constant speed)
Decrease
Smooth/small
Less efficient
Low to high
Somewhat smaller
7 Operation
100% (maximum value)
Double the standard speed
Increase
Significant/large *1
Efficient
Low
Somewhat larger
EN - 45

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Irob 401Irob 301

Inhaltsverzeichnis