Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 121

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
®
iROB
501, iROB
401, iROB
F35: Saving necking detection sensitivity
Defines whether necking detection sensitivity automatically corrected by function is reset to the preset value
after the welding process ends.
Set internal functions F36/F37.
1
Activate internal function F34.
2
If the free welding wire end and the welding conditions are subject to dramatic changes between
the welding processes, switch off this function.
Adjustable range
Default value
Storage option
Description
F36/F37: Adjusting spatter control (P1P/P2P)
This function is available only if the internal function F34 is deactivated.
Switch off internal function F34.
1
Display internal function F36 (spatter adjustment P1P) and perform the welding process with this display.
2
Increase or decrease the value of internal function F36 and perform the welding process again.
3
Repeat this step within the adjustable range −100 to 100 until the desired result is achieved.
4
Display internal function F37 (spatter adjustment P2P) and perform the welding process with this display.
5
Increase or decrease the value of internal function F37 and perform the welding process again.
6
Repeat this step within the adjustable range −100 to 100 until the desired result is achieved.
7
Adjustable range
Default value
Storage option
Description
F38: Switching on advanced welding circuit resistance measurement
The arc voltage can be determined via the corresponding welding power source terminal.
Use the optional arc voltage test line with a line length ≥ 30 m. Switch the direct arc voltage detection
terminal to the component-side welding power source terminal or the wire feeder terminal. Extending the
welding power supply line without a component-side test line connection can dramatically increase
the amount of spatter generated. In this case, use of the optional arc voltage test line can drastically limit the
amount of spatter.
Adjustable range
Default value
Storage option
Description
F43: CAN ID
If several welding power sources are connected to a PC monitoring system, the ID for the CAN bus can
be set here.
Adjustable range
Default value
Storage option
Description
®
301
ON/OFF
OFF
Yes
OFF: Necking detection sensitivity is not saved.
ON: Necking detection sensitivity is saved.
−100 to +100
0
F36: Yes
F37: No
Sets the control parameters for spatter control.
ON/OFF
OFF
No
OFF: Arc voltage detection input inactive.
ON: Arc voltage detection input active.
1 to 16
1
No
Defines the CAN ID number to be used with the PC monitoring
system, etc.
7 Operation
EN - 41

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Irob 401Irob 301

Inhaltsverzeichnis