or when the machine requires this procedure to be
performed by displaying the E 1 error message.
Calibrate as follows:
-
select the sensitivity calibration icon in the
configuration programme menu;
-
Fit a wheel of average dimensions (diameter
no less than 14") and preferably with a small
imbalance only on the wheel balancer.
-
perform a spin;
-
At the end of the spin, fix the calibration
weight supplied with the machine on the
shaft assembly bell as indicated in figure 22.
-
perform a second spin;
-
At the end of the spin, change the position of
the calibration weight on the shaft assembly
bell as indicated in figure 23
-
Perform a third spin. This last calibration phase
70
consists of three consecutive spins executed
automatically.
If the calibration has been successful, a permis-
sion acoustic signal goes off at the end of the
spin; otherwise, the E 2 message is temporarily
displayed.
Notes:
- Once the procedure is finished, remove the
calibration weight.
-
Press the key to interrupt the calibration pro-
cedure at any time.
-
This calibration is valid for any kind of wheel.
6.4. Service
This programme displays some data that are
used to test machine operation and to detect
the malfunctioning of some devices. Since these
data are not useful for the operator, it is recom-
mended that only technical support technicians
consult them.
6.5. C emergency system release (wheel
clamping device)
This programme allows, in case of emergency,
the device C to be opened when it is NOT
possible to release the wheel using the control
pedal C (L, Fig.10).
In order to operate the C system release press
22
the
automatically make several attempts to open the
device.
23
EM9980 TouchlessLine - Operator's manual
button; the machine will