BVS ID-M1280xF1-xx-xxx
Error
The BVS ID signals the error
status "System Error"
The BVS ID signals the error
status "System Error"
The BVS ID signals the error
status "System Error"
The BVS ID signals the error
status "System Error"
Not every inspection result is
transferred to the FTP server.
40
english
Cause
"overheating"
"loading of the inspection
program has failed"
"a critical error has occurred
during tool execution"
"camera is inaccessible"
Connection to the FTP server
is too slow.
Action
Once the internal temperature has
decreased again, the system will
automatically reset the error condition.
However, it is likely that with the same
setup, the problem will reappear.
Possible approaches:
1.
Reduce ambient temperature.
2.
Improve heat dissipation.
3.
Reduce the exposure time of the
internal LEDs.
Possible approaches:
1.
Manually load another inspection
program in config mode, then manually
try to load the desired inspection
program.
2.
Create a new inspection program.
Possible approaches:
1.
Power off the system and turn it on
again.
2.
If the error occurs again immediately,
load another inspection program or
create a new inspection program.
Possible approaches:
1.
Power off the system and turn it on
again.
Possible approaches:
1.
Export only reports without images.
2.
A faster connection to the FTP Server.