ABIBUG 300
Tab. 8
Faults and troubleshooting
Fault
Display on RED.
Error/error code on the
remote control display.
Display failed.
Welding wire is not fed.
Welding wire is stuck in the
contact tip.
Pore formation in the welding
seam.
High weld spatter.
Melting of molten bath.
Short-circuiting ignition
power.
Failure or malfunction.
Cause
Error in operation.
Defective hardware/software.
LED is defective.
Weld penetration on the contact tip.
Wire feeder/wire supply line defective.
Insufficient gas flow.
Gas flow is too high/too low.
Gas cylinder empty.
Gas diffuser defective/clogged.
Cable length changed.
Connection plug changed.
10 Faults and troubleshooting
Troubleshooting
► Switch off the device at the On/Off switch.
The LED is extinguished.
► Switch on the device at the On/Off switch
after 60 seconds. If the LED continues to be
illuminated red, check the error code and
remedy as needed.
10.1 Error codes and causes on
page EN-65
► Contact the service team if necessary.
► Replace the hardware.
9 Maintenance and cleaning on
page EN-51
► Contact the service team if necessary.
► Re-download the software.
Observe the information in the software
operating instructions.
► Switch off the device at the On/Off switch
and decommission the device.
8 Decommissioning on page EN-51
► Have the service team replace the LED.
► Replace the contact tip.
Observe the operating instructions for
the welding torch.
► Have the service team replace the wire
feed unit.
► Check the gas regulation of the gas
cylinder with the pressure reducer, and
adjust if necessary.
► Carry out the gas test. Press the <SHIFT>
and <GAS TEST> buttons on the remote
control.
► Check the gas regulation of the gas
cylinder with the pressure reducer, and
adjust if necessary.
► Check the gas regulation of the gas
cylinder with the pressure reducer, replace
the gas cylinder.
► Replace the gas diffuser.
Observe the information in the welding
torch operating instructions.
► Use only the supplied connection cable
and supply lines.
EN - 57