BOS R254K-UUI-RE10-S4
Photoelectric Sensors
3
Overview of IO-Link Data and Functions (continued)
Event Code
Event Type
0x8D12
Warning
(36114)
0x8D13
Warning
(36115)
0x8D15
Warning
(36117)
0x8D20
Warning
(36128)
0x8D22
Warning
(36130)
0x8D23
Error
(36131)
0x8D24
Warning
(36132)
0x8D25
Error
(36133)
0x8DC0
Notification
(36288)
Tab. 3-12: Events – Overview
www.balluff.com
Description
The defined threshold of the device-internal humidity
was exceeded.
► Check installation and ambient conditions.
One or more extreme conditions present.
Overload at pin 2
► Check wiring.
Device temperature lower warning – The set lower
temperature warning threshold is below the minimum
value.
Warning limit for write cycles reached – maintenance
monitoring no longer guaranteed – for information
purposes only.
Write cycle limit reached – saving no longer ensured
– replacement recommended.
Parameter write error – for information purposes
only.
Parameters not consistent – basic settings are used,
service required.
Teach-in timeout – The current teach process took
too long and was interrupted.
Device Status
1 – Maintenance-Required
0 – Device is operating properly.
2 – Out-of-Specification
0 – Device is operating properly
0 – Device is operating properly
1 – Maintenance-Required
0 – Device is operating properly
4 – Failure
0 – Device is operating properly.