R911336188 | PSI 6xCx.727
8
Status codes
In case of a general fault, the status code is on the output. In case of a welding
fault, the additional code with an offset 1000 is on the output.
Tab. 10: Status codes
Code (decimal)
Meaning
00
OK
80
Stop / no 24V
81
Weld without command
84
Battery fault
85
Memory deleted == RAM checksum error
86
Data download started
87
No schedule programmed == invalid parameters
88
Hardware fault
89
Serial I/O bus fault (only for timers with a serial I/O bus)
90
Half-cycle monitoring
91
Circuit breaker tripped
92
External over-temperature
93
Synchronization fault
94
Start inhibited
95
Program parity error
98
Programmed value too high
100
Supply voltage fault
115
PSQ fault
160
Heat sink temperature too high
164
Transformer temperature too high
165
Hardware fault driver module
166
24V supply voltage fault
1001
Current measurement circuit open
1002
Current measurement circuit shorted
1003
No primary voltage 1.HW
1004
Primary voltage measuring fault
1005
Reweld by timer active
1006
Inhibit monitoring mode active
1007
Ignition turned off during schedule
1008
KSR block ON - active
1010
No current (standard mode)
1011
No current PreWLD (mixed mode)
1012
No current MainWLD (mixed mode)
1013
No current PstWLD (mixed mode)
Bosch Rexroth AG
43/47
Status codes