R911381576 | PRC 7x00-Lx/Wx-403
Bosch Rexroth AG | Electric Drives and Controls
After reset of error the output "magnet valve (water flow)" will be switched on
again.

7.1.11 Supervision of minimum current

The time within which the current has to exceed a minimum threshold is
adjustable. If this threshold is not exceeded on average, the sequence is stopped
and an error message occurs.
8

Status codes

Tab.10: Status codes
Code (decimal)
Meaning
0
No error
10000
PLC - Module call with wrong data type
10001
PLC - Module can not find data element
10002
PLC - Abo still not active
10003
PLC - Abo not exists
10004
PLC - Abo exists already
10005
PLC - IPC error
10006
PLC - Timeout
10007
PLC - Spot selection has been changed unlicensed
10008
PLC - Selected spot is not existing
10009
PLC - Tip dress aborted with error
10010
PLC - Tip change aborted with error
10011
PLC - Gun change aborted with error
10012
PLC - Tip dresser change aborted with error
12000
Tip dresser changed
12001
Tip dresser in prewarnung
12002
Tipdresser at end of life
13000
Electrode dressed
13001
Electrode changed
13002
Gun component changed
13003
Gun mechanics
13004
Electrode has to be dressed
13005
Elektrode has to be replaced
13006
Gun component in prewarning
13007
Gun component at end of life
14000
Movement aborted
14001
Unknown command