32/47
Bosch Rexroth AG
Connection diagram
Stop circuit:
Floating contact
max. load:
24VDC / 3A
I/O - Board supply
with stop circuit
External logic supply
Option 2
Stop circuit:
Floating contact
max. load:
24VDC / 3A
Internal I/O - Board
supply with stop
circuit
Logic supply by
Standby - Supply
Option 3
Stop circuit:
Floating contact
max. load:
24VDC / 3A
External I/O - Board
supply with stop
circuit
Logic supply by
Standby - Supply
Option 4
Fig. 3:
Connection diagram examples
R911336188 | PSI 6xCx.727
24VDC I/O
1
0V I/O
2
3
4
5
24VDC external
6
0VDC external
7
8
9
24VDC standby
10
0VDC standby
11
12
24VDC Fan
13
0VDC Fan
14
24VDC I/O
1
0V I/O
2
3
4
5
24VDC external
6
0VDC external
7
8
9
24VDC standby
10
0VDC standby
11
12
24VDC Fan
13
0VDC Fan
14
24VDC I/O
1
0V I/O
2
3
4
5
24VDC external
6
0VDC external
7
8
9
24VDC standby
10
0VDC standby
11
12
24VDC Fan
13
0VDC Fan
14
Stop
24VDC
Internal
power
X
supply
4
0VDC
24VDC
Internal
Logic
0VDC
Internal
24VDC
power
0VDC
supply
Stop
24VDC
Internal
power
X
supply
4
0VDC
24VDC
Internal
Logic
0VDC
Internal
24VDC
power
0VDC
supply
Stop
24VDC
Internal
power
X
supply
4
0VDC
24VDC
Internal
Logic
0VDC
Internal
24VDC
power
0VDC
supply