Installation
Fig. 23 Transport safeguard in feet
Fig. 24 Feet with bolts
Fig. 25 Order of feet
Note: The bolts are an integral fixture for the machine. Without the bolts, adjustment can-
not checked at a later point in time or the machine cannot operate at a different site.
48
Unscrew the transport safeguards (Fig. 23/1) from
the four feet of the imaging unit.
Remove the four adjusting bolts (Fig. 24/1) for
adjusting the height of the imaging unit from the
accessories kit and insert them into their feet (Fig.
24/2).
Unscrew the yellow feet of the imaging unit (Fig.
19/2) until the lower edge of the marking on the
bolts is flush with the upper edge of the respective
foot.
Raise the machine base in steps of max. 5 mm by
adjusting feet 1, 2, and 3 (Fig. 25) until the marking
on the bolts is reached.
Turn foot 4 down until it touches the floor and then
give another full turn. Check the height set on feet
1, 2, and 3 and readjust if necessary.
Lock the machine feet nuts.
Remove the bolts and keep them in a safe place
(see Fig. 22).