Safety
For the operating company of a print shop, it is important that the exposure limits regarding breath-
able air in the work area (where the platesetter is located) are adhered to. The air exchange must be
arranged in such a way that the measured dust particles are regularly below the exposure limit val-
ues. In accordance with the state of the art, this can be achieved with an 8 to 10 air change rate per
hour. If this is not the case at the installation site, the operating company should install an additional
exhaust system.
When installing the machine, pay attention to the information in the "Installation" and
Data" chapters.
In order to provide proper ventilation, ensure that there is sufficient distance between the machine
and the wall or between the machine sides and other equipment when the equipment is installed.
The machine
- should not be installed in the proximity of air conditioning facilities,
- must be protected against direct sunlight or spotlights fitted in the room,
- must be protected against moisture.
In order to meet radio interference suppression requirements, only screened data cables may be
used.
Because the installation site must have clean conditions, the Suprasetter may not be operated in sites
where paper is being printed or paper finishing devices are running.
The required ambient conditions (see Technical Data chapter) must be observed for at least 12 hours
after power-off so that the Suprasetter is not damaged by condensation.
Power Supply
The Suprasetter is connected to the inhouse power supply either permanently with terminal block KL1
and the power cable or with a suitable industrial connector. A preconfigured power cable for the
device can be included in the shipment.
The national regulations and connector specifications must be observed when connecting the device.
During connection, make sure to follow the data in the table in
connection variants", page
nection can destroy the power supply module or drum drive of the device.
The protective conductor current of this device is ≤ 10 mA. That is why 6 mm² is selected for the
cable cross-section of the protective conductor.