Secondary parameters
Secondary parameters
Welding current
Twin pulse relation
Twin pulse curr. change
Twin pulse frequency
Start current time
Start current
Start Arc length corr.
Start wire feed speed
Start welding voltage
Start welding voltage +−
Wire creep speed
Gas pre-flow
Tab. 1:
Secondary parameters
Main level
Level 1
Set Job
(Job selection)
Editing mode for Set and
Job names
Extras
1: Machine data
2: Diagnosis
01.21
Mode
X
X X X X X X X X X X
X
X X
X
X X
X
X X
X X X X X X X X X X X X X X
X
X X X X X X X X X X
X X X X X X X X X X X X X
X X X
X X X X X X X X X X X X X
X X X X X X X X X X X X X
Level 2
Operating system Master
Operating system process
Operating system DMR
Welding programmes
Operating hours counter
Configuration
Option
Last error messages
Module temperatures °C
Op. voltages 15/24V
Cooling system/gas flow rate
Motor current
Arc power
X A
%
%
Hz
X s
X %
%
X
m/min 0.1
X
V
V
X
m/min 0.1
X X s
By pressing the "Tiptronic" S10 button Tiptronic mode is
switched on. Set and job names appear in the multifunction
display.
By simultaneously pressing the "Down" S12 and "Up" S13
buttons, edit mode is switched on.
Buttons "Down" S12 and "Up" S13 are used to move the
cursor.
Move the cursor with the buttons Signs can be selected or
edited with buttons (+) S3 and (-) S9.
Master operating system version number
Version number operating system process
Motor assembly (assemblies) version number
Welding programmes version number
Welding time display in h, min, sec
the machine type and the detected power module (with
maximum current) and serial number are displayed alter-
nately
Display of activated software options, such as e.g., seam
tracking, weld data
Display of the last three error messages in the error memory
(0=last error, 2 = oldest error)
Temperatures of the power modules in °C
Display of the operating voltages (15V/24V) of the pc-board
DP-MAPRO
Display of the coolant flow rate and shield gas flow rate in l/
min
Display of the motor currents of the feed units of main and
intermediate drive and push-pull torch in A
Display of the last measured arc power in kW
909.2599.9-06
Range
1
5...maximum
1
50
20...80
1
25
5...50
0.1
1,5
0.5...5
0.1
1.0
0.0...99.9
1
120 / 135 20...200
1
100
60...140
10
0.5...25.0
0.1
18
10.0...45.0
0.1
+2.0
-20.0...+20.0
1.0
0.5...25.0
0.1
0.1
0.0...10.0
Note
Only with..
(Electrode)
- 57 -