High-pressure hose
7
Fastening high-pressure hose
8
Fastening trigger gun
9
Fastening trigger gun
10
Trigger gun lever
11
Water inlet from water reservoir
1
Stop cock
2
High-pressure cleaner hydraulic connection
3
Water inlet for high-pressure pump
4
Safety information
Connection to a drinking water line
WARNING
Return flow of dirty water into the drinking water network
Health risk
Observe the regulations of your water supply company.
According to applicable regulations, the device must never be
used with the drinking water network without a system separator.
Use a system separator from KÄRCHER or a system separator
as per EN 12729 Type BA. Water that has flowed through a sys-
tem separator is classified as undrinkable. Always connect the
system separator to the water supply and never directly to the
water connection on the device.
Before initial startup
WARNING
Risk of injury from high-pressure jet
Do not direct the high-pressure jet at persons, animals, live elec-
trical equipment or at the device itself.
Protect the device high-pressure cleaner frost.
ATTENTION
Environmental pollution through oil
Clean engines only at locations having an appropriate oil separa-
tor.
Note
Only nozzles of the sizes listed in the technical data may be used.
If you have not already done so:
1. Connect the high-pressure hose and spray lance.
2. Connect the water supply hose and open the stop cock of the
water inlet.
Operation
Note
The high-pressure cleaner may be operated only at an engine
speed of 1600 rpm and only in work mode.
1. Check the water filling level and fill the water reservoir of the
MC 130 if necessary.
2. Open the stop cock of the water inlet.
3. Put travel direction lever in the NEUTRAL position - centre po-
sition and start the motor.
4. Remove the trigger gun and high-pressure hose from storage.
5. Switch on the PTO work hydraulics.
84
Operation
6. Press F1 function key on the display and switch on the high-
pressure cleaner.
Engine speed automatically increases to 1600 rpm.
A "high pressure" symbol appears in the display.
Switch the waste container high-pressure cleaner on and off
1
Additional socket-outlet, 12 V
2
Raise the waste container/attachment frame
3
Lower the waste container/attachment frame
4
7. Switch on the high-pressure cleaner with the switch next to the
driver's seat.
8. Unlock the trigger gun.
9. Pull the trigger on the trigger gun and commence cleaning.
Note
For first use or when the water reservoir is empty, the high-pres-
sure cleaner must be vented:
10.Operate the high-pressure cleaner without the nozzle until
there is no more air in the system.
Shutting down
1. Close the trigger gun.
2. Switch off the high-pressure cleaner with the switch on the
right of the driver's seat.
3. Switch off the work hydraulics.
4. Actuate the trigger gun until the device is depressurised.
5. Actuate the safety lever of the trigger gun to prevent the gun
trigger from being unintentionally triggered.
6. Fasten and secure the trigger gun with spray lance and high-
pressure hose in storage.
Note
If the high-pressure cleaner is not needed, for example during
winter operation (spreading salt and other work):
7. Blow out the system with compressed air - see chapter Frost
protection.
8. Remove the high-pressure gun with spray lance and high-
pressure hose from the device.
English