14.4.1 Establishing a 400V connection
To connect the machine to the electrical mains, proceed as follows:
Use a suitable device to check that the zero connection and earthing are working properly.
Check that the supply voltage and its frequency correspond to the specifications on the
machine nameplate. A deviation of ± 5 % from the value of the supply voltage is per-
missible. For example, a machine with a working voltage of 380 V can work in the volt-
age range from 370 to 400 V. The machine can be operated with a working voltage of
380 V in the voltage range from 370 to 400 V. The machine can also be operated with a
working voltage of 380 V in the voltage range from 370 to 400 V. There must be a
short-circuit fuse in the power supply of the machine!
For the required cross-section of the supply cable, please refer to the current carrying ca-
pacity table.
The use of a cable of type Н07RN (WDE0282) is recommended, whereby measures must
be taken to protect against mechanical damage.
Connect the supply cable to the appropriate terminals in the input box (L1, L2, L3, N, РЕ) -
see following figure. If there is a СЕЕ plug, the connection to the mains is made by an
appropriately supplied СЕЕ coupling (L1, L2, L3, N, РЕ).
Plug connection 400V:
14.5 Connecting to a compressed air supply
Die Druckluft-Einheit am Druckluftanschluss mit Druckluft verbinden.
Die Druckeinstellung sollte auf ca. 6 bar eingestellt werden.
HOLZMANN MASCHINEN GmbH
Remove cover
www.holzmann-maschinen.at