14.4.1 Establishing a 400V connection

To connect the machine to the electrical mains, proceed as follows:
 Use a suitable device to check that the zero connection and earthing are working properly.
 Check that the supply voltage and its frequency correspond to the specifications on the
machine nameplate. A deviation of ± 5 % from the value of the supply voltage is per-
missible. For example, a machine with a working voltage of 380 V can work in the volt-
age range from 370 to 400 V. The machine can be operated with a working voltage of
380 V in the voltage range from 370 to 400 V. The machine can also be operated with a
working voltage of 380 V in the voltage range from 370 to 400 V. There must be a
short-circuit fuse in the power supply of the machine!
 For the required cross-section of the supply cable, please refer to the current carrying ca-
pacity table.
 The use of a cable of type Н07RN (WDE0282) is recommended, whereby measures must
be taken to protect against mechanical damage.
 Connect the supply cable to the appropriate terminals in the input box (L1, L2, L3, N, РЕ) -
see following figure. If there is a СЕЕ plug, the connection to the mains is made by an
appropriately supplied СЕЕ coupling (L1, L2, L3, N, РЕ).
Plug connection 400V:

14.5 Connecting to a compressed air supply

Die Druckluft-Einheit am Druckluftanschluss mit Druckluft verbinden.
Die Druckeinstellung sollte auf ca. 6 bar eingestellt werden.
HOLZMANN MASCHINEN GmbH
Remove cover
www.holzmann-maschinen.at
ASSEMBLY
5-wire conductor
26
KAM535

Werbung