Chapter 3
Note
2 5 4
8008684/TI59/2009-12-09
Product Description
plug of the receiver) has been pressed and released. The reset
button is connected locally to the extension plug of the receiver
using a pre-assembled cable from SICK. The reset button does not
need to be wired up at the switch cabinet (see Section 5.9).
The reset button must also be pressed when the device is switched on.
The restart inhibit (RES) cannot be activated in a cascade. The safety
evaluation unit LE 20 can be used to provide this function in cascades.
Fig. 3-8: RES not possible in cascade
S = Sender
R = Receiver
3.3
Display elements
Fig. 3-9: Display elements of C 2000, M 2000 and M 2000-A/P
S = Sender
R = Receiver
= LED yellow
The C 2000, M 2000 and M 2000-A/P units have the following
display elements:
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Multibeam Photoelectric Safety Switch M 2000
= Machine
= Reset button
= 7-segment-display, sender
= 7-segment-display, receiver
= LED yellow
Operating Instructions
Safety Light Curtain C 2000
= LED amber
= LED red
= LED green