10.12 Independent setting of undelayed loops

This menu item allows you to set the undelayed loops to only raise the alarm after the exit delay time has
passed if a delayed loop has been activated.
Memory location
(press the displayed button on the
control panel)
41
Code =
With this code you can set the alarm sounding for undelayed loops to operate only after the exit
delay time has passed.
0 =
Alarm delay off (factory setting)
1 =
Alarm delay on
Explanation:
0 =
If a sensor connected to an undelayed loop is activated, the alarm control centre immediately
sounds the alarm.
1 =
If a sensor connected to an undelayed loop is activated, and then a sensor If a sensor connec-
ted to a delayed loop is activated, the delay time will begin and must pass before the alarm is
sounded by the alarm control centre.
You can however avoid the alarm by disarming the alarm control centre at the remote control
panel.

10.13 Programming telephone numbers

This is where you programme the telephone numbers to be called by the telephone dialler in the case of an
alarm. The dialler is only activated once the telephone numbers are entered.
Once the alarm system has raised the alarm and the corresponding zones are activated, the telephone
dialler begins to call the telephone numbers. After that it begins to transmit the text and/or signals. If the
person called takes the call a little later, it can be the case the alarm control centre has already begun to
play the message.
It is recommended that you test the programming undertaken in this chapter to ensure the cor-
rect telephone number is entered correctly and the desired settings have been made correctly.
See chapter "10.9. Second Entry Delay". Inform the person to be called beforehand that this is
only a test!
The telephone dialler function must be switched on (Chapter 10.18).
This is the factory setting and you do not need to make any changes.
Code
(enter the desired code on the control
panel)
0 or 1
Confirmation
(press the displayed button on
the control panel)
#