D-138
Parameter Reference
Name
PNO
0611
App Control Word.SWITCH ON
0612
App Control Word.ENABLE VOLTAGE
App Control Word.NOT QUICKSTOP
0613
App Control Word.ENABLE OPERATION
0614
0618
App Control Word.RESET FAULT
0619
App Control Word.EXTERNAL FAULT
App Control Word.USE JOG REFERENCE
0623
0624
App Control Word.REVERSE DIRECTION
0625
App Control Word.AUTO INITIALISE
0626
App Control Word.EVENT TRIGGERED OP
Comms Control Word
0627
0628
Comms Control Word.SWITCH ON
0629
Comms Control Word.ENABLE VOLTAGE
0630
Comms Control Word.NOT QUICKSTOP
Comms Control Word.ENABLE OPERATION
0631
0635
Comms Control Word.RESET FAULT
0636
Comms Control Word.EXTERNAL FAULT
Comms Control Word.USE COMMS
0638
CONTROL
Comms Control Word.USE COMMS
0639
REFERENCE
Comms Control Word.USE JOG
0640
REFERENCE
0641
Comms Control Word.REVERSE DIRECTION Parameters::Motor Control::Sequencing
Comms Control Word.AUTO INITIALISE
0642
Comms Control Word.EVENT TRIGGERED
0643
OP
Control Word
0644
0645
Control Word.SWITCH ON
0646
Control Word.ENABLE VOLTAGE
0647
Control Word.NOT QUICKSTOP
Control Word.ENABLE OPERATION
0648
Control Word.RESET FAULT
0652
Path(s)
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing
Type
Default
Range
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
0:SWITCH ON
1:ENABLE VOLTAGE
2:NOT QUICKSTOP
3:ENABLE OPERATION
7:RESET FAULT
8:EXTERNAL FAULT
WORD
0000
10:USE COMMS CONTROL
(bitfield)
11:USE COMMS
REFERENCE
12:USE JOG REFERENCE
13:REVERSE DIRECTION
14:AUTO INITIALISE
15:EVENT TRIGGERED OP
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
0:SWITCH ON
1:ENABLE VOLTAGE
2:NOT QUICKSTOP
3:ENABLE OPERATION
7:RESET FAULT
8:EXTERNAL FAULT
WORD
10:USE COMMS CONTROL
(bitfield)
11:USE COMMS
REFERENCE
12:USE JOG REFERENCE
13:REVERSE DIRECTION
14:AUTO INITIALISE
15:EVENT TRIGGERED OP
BOOL
BOOL
BOOL
BOOL
BOOL
Units
WQ
View
Notes MBus
ALWAYS
ENGINEER
2
01749
ALWAYS
ENGINEER
2
01751
ALWAYS
ENGINEER
2
01753
ALWAYS
ENGINEER
2
01755
ALWAYS
ENGINEER
2
01763
ALWAYS
ENGINEER
2
01765
ALWAYS
ENGINEER
2
01773
ALWAYS
ENGINEER
2
01775
ALWAYS
ENGINEER
2
01777
ALWAYS
ENGINEER
2
01779
ALWAYS
TECHNICIAN 2
01781
ALWAYS
TECHNICIAN 2
01783
ALWAYS
TECHNICIAN 2
01785
ALWAYS
TECHNICIAN 2
01787
ALWAYS
TECHNICIAN 2
01789
ALWAYS
TECHNICIAN 2
01797
ALWAYS
TECHNICIAN 2
01799
ALWAYS
TECHNICIAN 2
01803
ALWAYS
TECHNICIAN 2
01805
ALWAYS
TECHNICIAN 2
01807
ALWAYS
TECHNICIAN 2
01809
ALWAYS
TECHNICIAN 2
01811
ALWAYS
TECHNICIAN 2
01813
NEVER
TECHNICIAN
01815
NEVER
TECHNICIAN
01817
NEVER
TECHNICIAN
01819
NEVER
TECHNICIAN
01821
NEVER
TECHNICIAN
01823
NEVER
TECHNICIAN
01831
AC30V series Variable Speed Drive