PNO
Parameter Descriptions
0398
iq
Current in the torque axis (Vector Control)
0399
Actual Torque
Calculated torque, based on the Iq current.
0400
Actual Field Current
Calculated field, based on the Id current.
0401
Motor Current Percent
This diagnostic shows the level of rms line current being drawn from the drive as a percentage of the rated current of the relevant
motor definition.
0402
Motor Current
This diagnostic shows the level of rms line current in Amps being drawn from the Drive.
0403
100% Stack Current A
This diagnostic indicates the stack rating in Amps. This reduces as a function of pwm switching frequency.
0404
Stack Current (%)
Stack current percentage.
0405
Motor Terminal Volts
Volts between motor phases in Vrms.
0406
CMTemperature
Temperature of Control Module in
0407
Heatsink Temperature
Power stack heatsink temperature in
0408
Elec Rotor Speed
Mechanical speed (shaft speed in
0409
Heatsink OT Trip
Heatsink Overtemp Trip Level.
0410
Heatsink OT Warning
Heatsink Overtemp Warning level.
0411
Heatsink Hot Warning
Heatsink Hot Warning Level.
AC30V series Variable Speed Drive
o
Centigrade.
o
Centigrade.
rev
/
) x number of motor pole pairs. This parameter is not filtered.
s
D-37
Parameter Reference