Herunterladen Inhalt Inhalt Diese Seite drucken

Parker AC30V Benutzerhandbuch Seite 342

Vorschau ausblenden Andere Handbücher für AC30V:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

D-114
Parameter Reference
PNO
Parameter Descriptions
0350
Inv Time Up Rate
Ramp value to ramp up current when overload condition disappears
0351
Inv Time Down Rate
Ramp value to reach the aiming point under prolonged overload condition
0352
Inv Time Warning
The protection starts to integrate overload conditions
0353
Inv Time Active
The drive protection is limiting the output current
Functional Description
Feedback Amps
Move to Stack %
Convert to Motor %
Short Overload : is using 180% of the Heavy Duty rating, for 3s.
Long Overload : is using the overload mode selected in the Duty Selection parameter.
Inv Time in Motor % is used to limit the current. It is one of the inputs of the Current Limit Function features
Stack Short overload
arbitration
Stack Long overload
Motor Load (Only for IM Motor)
Motor overload (
150%, 60s)
Inv Time Output
Convert to Motor %
Min
Inv Time in Motor %
AC30V series Variable Speed Drive

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis