2.14.2 Stroke Adjustment Range and Timing of the Stroke Movement of the Transport Foot

Gauge 10
4
2
3
In the position "2 mm" of the stroke height setting wheel both pressure
feet should conduct the following strokes:
Hopper foot:
2,0 mm
Transport foot: 2,5 mm
Caution Risk of Injury!
Before adjusting turn the main switch off.
Stroke adjustment range
Loosen screws 3.
Place gauge 10 on the two cast walls of the arm.
Swing block 2 until the bolt of the stroke rocker 4 touches the
gauge 10.
For the axial fixing of the shaft push the block against the bush.
Tighten the screws again.
Remove the gauge.
Attention!
After the setting is made at the factory the screws 3 are secured with
yellow paint and may no longer be altered.The eccentric 5 on the arm
head must lie in its base position. Its slit must be turned 45° to the
back in the upper semicircle.
Stroke timing
Arrest the machine in slot D.
Loosen the screws on the stroke eccentric.Turn the stroke
eccentric on the arm shaft so that when the stroke rocker 4 moves
the stroke lever 8 remains at rest.Tighten screws again
Loosen screw 9. Turn stroke lever 8 so that both sewing feet lay
onto the needle plate. Tighten screw 9 again.
Note:
After this setting both sewing feet conduct the same stroke.
9
8
7
6
5
2
27