AKD Benutzerhandbuch | 25.32.19 REC.TRIGTYPE

25.32.19 REC.TRIGTYPE

General Information
Type
Description Sets the trigger type.
Units
Range
Default
Value
Data Type
See Also
Start Ver-
sion
Variants Supported
AKD BASIC
AKD SynqNet
AKD EtherNet/IP
Fieldbus Information
Fieldbus Index/Subindex Is 64 bit? Attributes Signed? Object Start Version
Modbus 728
Description
REC.TRIGTYPE sets the type of trigger.
Input values are as follows:
Value
0
1
2
3
Related Topics
 Oszilloskop (s: 241)
894
KOLLMORGEN | Mai 2013
R/W Parameter
0 = immediate
1 = command
2 = parameter
3 = boolean
0 to 2
0
Integer
REC.TRIG (s: 888), REC.TRIGPARAM, REC.TRIGVAL, REC.TRIGSLOPE
REC.TRIGPOS
M_01-00-00-000
Variant
No
Recording starts immediately
Recording starts on the next command executed through the TCP/IP. The trigger loca-
tion in the buffer is set according to REC.TRIGPOS.
Recording starts per the values of REC.TRIGPARAM, REC.TRIGVAL, REC.TRIG-
SLOPE, and REC.TRIGPOS.
Recording starts when the value of REC.TRIGPARAM is 0 for REC.TRIGSLOPE = 0
or 1 for REC.TRIGSLOPE = 1
Supported
N/A
8 bit
No
M_01-03-00-000
Description