Setting MOTOR 1 torque
Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result, adjusts
obstacle detection sensitivity.
Use values below
(strong winds or very cold temperatures). In installations with gate leaves of different lengths, they torque value may
be set separately, setting a value for parameter
Setting MOTOR 2 torque
Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result, adjusts
obstacle detection sensitivity.
Use values below
(strong winds or very cold temperatures). In installations with gate leaves of different lengths, they torque value may
be set separately, setting a value for parameter
= -35%;
= -25%;
= 0%.
= +8%;
= +16%;
Setting obstacle impact force sensitivity MOTOR 1
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force exerted
on obstacles is too high, reduce the value of parameter
made to this parameter.
Setting obstacle impact force sensitivity MOTOR 2
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force exerted
on obstacles is too high, reduce the value of parameter
N.B: repeat the acquisition procedure after any change made to this parameter.
= minimum obstacle impact force ...
N.B.: only use these settings if the medium motor torque values are not suitable for the installation.
Medium motor torque. Recommended setting for adjusting force settings correctly.
= minimum obstacle impact force ...
Motor torque at 70% of the maximum value, intervention time 1 s. The use of the sensing edge is mandatory.
Motor torque at 80% of the maximum value, intervention time 2 s. The use of the sensing edge is mandatory.
Motor torque at 100%, intervention time 2 s. The use of the sensing edge is mandatory.
Motor torque at 100%, intervention time 3 s. The use of the sensing edge is mandatory.
Setting start acceleration MOTOR 1 during opening
Setting start acceleration MOTOR 2 during opening
= the gate accelerates rapidly at start of manoeuvre
...
= the gate accelerates slowly and progressively at start of manoeuvre.
Setting start acceleration MOTOR 1 during closing
Setting start acceleration MOTOR 2 during closing
= the gate accelerates rapidly at start of manoeuvre
...
= the gate accelerates slowly and progressively at start of manoeuvre.
Enable electric lock release reverse impulse
Disabled.
Enabled. The controller applies a brief closing force (max. 4 s) to release the electric lock.
MOTOR 1 opening speed setting (%)
MOTOR 2 opening speed setting (%)
=minimum speed
...
=maximum speed.
MOTOR 1 closing speed setting (%)
MOTOR 2 closing speed setting (%)
=minimum speed
...
=maximum speed.
106
SOLO ONLY for particularly lightweight installations not exposed to severe weather conditions
between
SOLO ONLY for particularly lightweight installations not exposed to severe weather conditions
between
= -16%;
= -8% (reduced motor torque = increased sensitivity).
= +25%;
= +35% (increased motor torque = reduced sensitivity).
= maximum obstacle impact force
= maximum obstacle impact force.
and
.
and
.
. N.B: repeat the acquisition procedure after any change
(or
different from
).