HANDLING AND INSTALLATION
All installation stages must be considered right
from production of the general layout. Before
starting these stages, as well as deciding the
place of installation, if necessary, the person au-
thorised to carry out these operations must or-
ganise a "safety plan" to protect the people di-
rectly involved, and he must also ensure strict
compliance with all legal requirements, espe-
cially those relating to mobile work-sites.
The place of installation must have all the con-
nections needed to supply the appliance and
dispose of the production residues, must be
suitably lit and must meet all legal health and
hygiene requirements to prevent the contami-
nation of the foods.
If necessary, fi x the exact position of each indi-
vidual appliance or subassembly by mark coor-
dinates to locate them correctly (see explana-
tory diagram).
IMPORTANT
ble for built-in installation.
WARNING
: Do not install the unit
next to walls made of fl ammable material.
WARNING
: Air inlets are required in
the room where the appliance is installed to
ensure a proper operation of the appliance
and to exchange the air in the room.
WARNING
: The air inlets should be
of appropriate size, protected by gratings,
and placed so that they cannot be obstruct-
ed.
3319981_inst_GB
INSTALLATION OF THE APPLIANCE
:The unit is not suita-
ROOM VENTILATION
WARNING
: Do not install the unit on
uneven, soft or sloped fl oors.
WARNING
: Leave a gap of at least 5
cm from the wall when installing the appli-
ance.
Install in accordance with the relevant legisla-
tion, regulations and specifi cations in the coun-
try of use.