Attribute 111, Position Status; Attribute 112, Accept Parameter - TR-Electronic LA Serie Gesamt-Bedienungsanleitung

Linear encoder magnetostriktiv
Vorschau ausblenden Andere Handbücher für LA Serie:
Inhaltsverzeichnis

Werbung

Parameterization

7.4.3.35 Attribute 111, Position Status

The Position
permissible measuring range. If the error "No magnet detected" is reported, either no
magnet is installed, the magnet is located in the damping zone or the number of
magnets configured does not agree with the real number. No analyzable measuring
signal can be output by the measuring system within the damping zone.
Data type
Access
Lower limit
Upper limit
Default
Value
0x00 00 00 00 No error
0x00 00 00 01 No magnet detected
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class

7.4.3.36 Attribute 112, Accept Parameter

Accept Parameter complies to the service code 0x16 (Save Parameter) and saves
the measuring system parameter into the non-volatile memory (EEPROM).
With write access ≠ 0 all changed attributes of all instances are stored permanently
and the acceptance of changed values for the instance attributes is performed.
Data type
Access
Lower limit
Upper limit
Default
Connection path, Packed EPATH with 8 bit class
0x20
Logical Type
= Class
 TR-Electronic GmbH 2014, All Rights Reserved
Page 154 of 183
Status reports whether all magnets are located within the
UDINT
Get
0
1
0
Description
0x23
0x24
Logical Type
Class #23
= Instance
USINT
Set / Get
0
255
0
0x23
0x24
Logical Type
Class #23
= Instance
TR - ELA - BA - DGB - 0023 - 06
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
0x01
0x30
Logical Type
Instance #1
=Attr.-ID
Printed in the Federal Republic of Germany
Default
X
0x6F
Attr.-ID #111
0x70
Attr.-ID #112
05/04/2018