11.5 Supplementary circuits
11.5.14

Y53, output isolating amplifier output: 4 mA to 20 mA

Category
Supplementary circuits
Function
Version, see option Y52
Connection
The customer connection is directly established at isolating amplifier XT-T2 (1) at terminals 7
and 9.
Parameter assignment
Isolating amplifiers are preset, no parameterization is required.
Cable routing
See option Y52
11.5.15
Y54, output isolating amplifier output: 0 V to 10 V
Category
Supplementary circuits
Function
Version, see option Y52
Connection
The customer connection is directly established at isolating amplifier XT-T2 (1) at terminals 8
and 9.
Parameter assignment
Isolating amplifiers are preset, no parameterization is required.
Cable routing
See option Y52