11.4.2
B61, display instrument "armature voltage"
Category
Display instruments
Function
Analog display instrument, door mounted, black front frame, 96 × 96 mm, scale ± maximum
DC voltage that can be reached (1.35 x line voltage) with center zero point. The measured
value is provided via an analog output of the SINAMICS DCM DC Converter.
Note
A maximum of six display instruments can be ordered for various display values. From a
total of three display instruments (B60, B61, B62, B64), option G60 must also be ordered.
Connection
Is connected up in the manufacturer's factory.
Commissioning
The analog output actually used depends on the combination of the selected options, and
must be taken from the circuit diagram on a project for project basis. According to the
project-specific solution, the parameter assignment should be defined using the operating
instructions for the SINAMICS DCM DC Converter and the List Manual, and should be
parameterized and tested during the commissioning phase.
Parameter assignment
Interconnect connector r52292 to the analog output.
Scaling of p52292: 100 % corresponds to p50078[0] × 3 × √2 / π
The scaling must be performed corresponding to the end of scale value of the measuring
instrument.
The analog output intended for this function must be parameterized on a project-for-project
basis.
SINAMICS DCM Cabinet
Operating Instructions, 04/2015, A5E36161239/RS-AA/001
Options
11.4 Display instruments
219