Power supply
AC voltage
DC voltage
Ripple (Smart devices)
Electrical isolation

16 Software development

34
4 wire: 180 V ... 250 V AC; 90 V ... 127 V AC ; power consumption < 4 VA
4 wire: 18 V . ..36 V DC, power consumption < 2.5 W; 2 wire: 12 V ... 36 V DC
HART max. ripple (measured at 500 Ω ) 47 Hz...125 Hz : U
max. noise (measured at 500 Ω ) 500 Hz...10 kHz : U
The evaluation electronics is electrically isolated from the power supply terminals with all four-
wire versions.
Software version and BA version
LUC-T
Instrument
SW/BA
and
software
No. V9H3
2.2/ from 08.99
7522
LUC-T
Instrument
SW/BA
and
software
No. V9H3
2.2/ from 08.99
7422
= 200 mV
PP
= 2.2 mV
eff
Modifications
VU 260 Z
from 1.7
actual version
DXR 275
Modifications
Device revision: 2
actual version
DD revision: 2