R911332442 | PSI 6xxx.326
6.2
Serial input/output array with Interbus-S
Serial input field
Tab. 6:
Bits
Inputs (control word)
0
Start
1
Reset fault
2
Reset fault with Weld complete
3
Reset fault and reweld
4
Weld on, external
5
6
7
Electrodes have been replaced
8
Tips have been dressed
9
10
11
Acknowledge dressing tool change
12
13
Start Dressing tool 1
14
Close gun 1
15
16
17
18
19
Start dressing tool 2
20
Close gun 2
21
22
Component End
23
Disable UIR mode
24
Set gun resistance
25
Reference weld for „New electrode"
26
Reference weld „Tip dressing"
27
Monitoring weld
28
Operate pressure sensor
29
Reserved
(Minimum electrode height)
30
31
32
Spot selection Bit 00 „1"
33
Spot selection Bit 01 „2"
34
Spot selection Bit 02 „4"
Bosch Rexroth AG
35/46
Input/Output array