Herunterladen Inhalt Inhalt Diese Seite drucken

Alarm Display - Sony LH51 Bedienungsanleitung

Digital readout
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8. Alarm Display

Display
Flashes
C L
RESET
P
When using the LH51-3
RESET
When using the LH51-1 or LH51-2
5
1
1
or
5
1
2
RESET
When using the LH52-3
5
2
3
RESET
66
When any one of the displays described below appears, reset and perform the operation from the
beginning.
Trouble
When the scale is not connected:
Turn the power off, connect the scale, and turn the power back on again.
Scale disconnected
The display will be reset to "0".
When an error occurs for the Z-axis when using the LH52:
Change the display settings as instructed in section 5-1-17 if the third axis is not
being used.
When the scale movement exceeds the maximum response speed of the counter
Excess speed
unit. (This alarm also functions when the machine receives a great shock.)
Overflow
When the display overflows, "F" is indicated in the most significant digit.
When the power fails momentarily during measurement.
Power failure
Error in stored data
When the stored data has been changed by noise, etc.
Note
When an error in the stored data is shown by "
axis is cleared. In addition, the machine setting contents may also be cleared.
In these cases, perform the following machine settings, and then make the settings again
according to "5-1. Initial Settings" (page 11).
Operating procedure
Turn on the power while holding down the X-
axis
key and the 1/2 key.
RESET
Press the Preset key.
Press the
key.
RESET
P
Press
or
5
5
1
1
Preset key.
P
Press the
key.
RESET
P
Press
keys and the Preset key.
5
2
3
Press the
key.
RESET
Causes
" flashing on the display, all the data for that
keys and the
1
2
P
Display
All digits light up
or

Werbung