7.2.2
Possible cases and their effects when connected via Ethernet
When connecting between the PC and ClipX the following cases may arise:
1.
No server in the network, the PC has no address (DHCP is used), and the ClipX is
likewise set to DHCP (factory default setting).
When using Windows XP or higher, temporary addresses are automatically
assigned by the PC (APIPA), the ClipX connection can be made.
2.
No server in network, PC has no setting or is using DHCP, the ClipX has a fixed
address
No connection can be established with this combination.
3.
No server in the network, PC and ClipX have a fixed address
A connection can normally be made only if the addresses of the PC and ClipX are in
the same network segment and both are using the same subnet mask.
4.
DHCP server in network, PC has a fixed address or uses DHCP, the ClipX has a fixed
address.
A connection can normally be made only if the addresses of the PC and ClipX are in
the same network segment.
5.
DHCP server in network, PC and ClipX are using DHCP
The connection can be established.
7.2.3
Set Ethernet address of PC
Procedure for Windows 10
1.
Use the
icon in the notification area of the task bar to open the Network and
Internet Settings (right mouse button).
2.
In the Change network settings section click on Change adapter options.
3.
Right click on the relevant adapter (port), select Properties and specify an Adminis-
trator account or confirm the security prompt.
4.
Select Internet protocol version 4 (TCP/IPv4) and click on Properties.
5.
Activate Use the following IP address and enter an address with which the first
three groups of numbers match the groups of numbers of the HBM device and only
the last group of numbers contains a different number between 1 and 254. The last
group of numbers must not match the one on the HBM device.
6.
For Subnet mask enter the same groups of numbers as are present on the HBM
device.
7.
Then click OK or Close to close all open dialogs.
See also
„Example" on page
72
74.
ClipX
Starting up the ClipX