Peak value with capture (block type 10)
Index
Subindex
0x510n
20
21
22
23
24
25
26
27
30
31
32
ClipX
Operation via fieldbus
Function
Input, the observed signal.
Input Hold channel.
Reset by.
Hold by.
Reset on.
Hold on.
Mode.
"Reset" command.
Output peak flag.
Output peak value.
Output captured value.
Value
0 ... 47, see
„List of signal refer-
ences" on page
218, UINT16.
Flag number 0 ... 63, see
tal flags: List of I/O flags (I/O
status)" on page
157. UINT8.
0: Reset at High level1: Reset at
Low level, UINT8.
0: Hold on High level
1: Hold on Low level, UINT8.
0: Maximum value
1: Minimum value, UINT16.
WO
Flag number 12 ... 19, 64, see
„Digital flags: List of I/O flags
(I/O status)" on page
UINT8.
21 ... 26, 48, see
„List of signal
references" on page
INT16.
„Digi-
157,
218,
201